Steel lintel sizes for openings

Keystone Lintels has teamed up with Roger Bisby from Skill Builder to provide you with the top 10 tips when installing a lintel. Play Video. Steel Lintels should be installed with a minimum end bearing of mm, bedded on mortar and levelled along its length and across its width.

Raise the inner and outer leaves simultaneously to avoid excessive eccentricity of loading, with a maximum height difference of mm Masonry should be laid on a mortar bed and all perpendicular joints should be filled. Allow the mortar to cure before applying floor or roof loads Temporary propping beneath a steel lintel is practised to facilitate speed of construction. When installing concrete floor units or other heavy components above a lintel, care should be taken to avoid shock loading and floor units should not be dragged into position.

Masonry immediately above the lintel should be allowed to cure. Point loads should not be applied directly onto lintel flanges.

Lintels - For above windows and doors providing structural support

Steel Lintels should have a minimum of masonry mm high between the flange and the application level of any form of loading. When the underside of a lintel is exposed, its appearance can be enhanced by the addition of lintel soffit cladding.

In accordance with BS EN and NHBC requirements all external wall lintels MUST be installed with a flexible damp proof course with the exception of those adequately protected by an eaves overhang or similar form of protection. Lintel should be centred in the cavity and the distance between lintel up-stand within the cavity and masonry must not exceed 10mm.

The practice of propping a lintel is sometimes used to facilitate speed of construction. It should only be introduced after initial masonry load has been applied to the lintel. Steel Lintels Installation Guide.

Technical Support. Tips for Installing Lintels Keystone Lintels has teamed up with Roger Bisby from Skill Builder to provide you with the top 10 tips when installing a lintel. The masonry above the lintel should be built in accordance with BS EN Do not cut lintels to length or modify them in any way without consulting an Keystone engineer. Ensure lintel is level along its length.

Lintel position within a cavity wall In accordance with BS EN and NHBC requirements all external wall lintels MUST be installed with a flexible damp proof course with the exception of those adequately protected by an eaves overhang or similar form of protection.

Lintel should be centred in the cavity and the distance between lintel up-stand within the cavity and masonry must not exceed 10mm Masonry should not overhang any flange by more than 25mm. Propping The practice of propping a lintel is sometimes used to facilitate speed of construction.

steel lintel sizes for openings

We use cookies to ensure that we give you the best experience on our website.If you want to create an opening for a new door in an exterior wall, it may seem like a straightforward process: Just knock out the appropriate amount of space, place the new door frame in the hole and clean it up so everything looks nice.

In truth, this should never be attempted because you may be damaging a load-bearing wall in the process, which could lead to extensive damage to the building or, if things go dramatically wrong, people getting hurt or even killed.

Especially when dealing with brick and concrete block walls, the installation of a lintel is required before opening up the load-bearing wall.

While installing a lintel in a block wall isn't a difficult process if you have a moderate amount of masonry experience, it still requires care, close attention and a number of safety procedures. Available in a variety of materials including wood, stone and concrete, most modern buildings use flat steel lintels. Installed into a load-bearing wall, a lintel redirects the load of the wall away from the material below it and into the building's foundation, allowing for the construction of new openings in the wall without risking critical damage to the entire building.

In structures built from brick, concrete or cinder block, the lintel is placed into the mortar between layers of the material. Lintels are easily available from most construction material manufacturers and large hardware stores, and though they aren't terribly difficult to install, you should not attempt to install a lintel into your wall without taking the appropriate precautions.

Check with your local governing office to ensure that your construction plan is legal, and consult a structural engineer or credible builder before proceeding. They will be able to tell you where a lintel can and should be placed as well as what material will be required for that lintel.

Lintels must always be at least millimeters longer than the gap they sit over, so the expert will likely give you the exact measurements required of your new lintel. Once you've consulted an engineer or builder and received approval for your construction project, you can begin the lintel installation process.

If you lack masonry experience, it is advisable to call a professional to complete the rest of this process in order to minimize the potential risk.

steel lintel sizes for openings

Steel lintels in concrete block walls are placed in the mortar between blocks, so the first step will be opening a space for the lintel itself. With the intended position of the lintel marked on the wall, carefully use an angle grinder or masonry saw to cut away the mortar.

Grind down parts of the concrete blocks if necessary, and then use a hammer and chisel to knock away anything remaining. Use a hammer drill with a millimeter masonry bit to clean up the gap in the wall so the lintel can be smoothly inserted. Once the space for the lintel is open, set it inside the gap and use a sledgehammer to gently knock it into place, making sure it is snug but without damaging any of the surrounding wall.

You may then secure the lintel by preparing and applying ready-mix mortar to the area around the lintel. Smooth the mortar to match the rest of the wall if necessary, and your lintel will be installed.

Blake Flournoy is a writer, reporter, and researcher based out of Baltimore, MD. As a handyman's apprentice operating out of the Atlanta suburbs, they made a name for themselves repairing appliances and installing home decor.Where a lintel will be subjected to gravity load condition 1 through 5 of Table R The maximum clear span of lintels with and without stirrups in flat walls shall be determined in accordance with Tables R The maximum clear span of lintels with and without stirrups in waffle-grid walls shall be determined in accordance with Tables R The maximum clear span of lintels with and without stirrups in screen-grid walls shall be determined in accordance with Table R Where required by the applicable table, No.

The smaller value of d computed for the top and bottom bar shall be used to determine the maximum stirrup spacing. Where stirrups are required in a lintel with a single bar or two bundled bars in the top and bottom, they shall be fabricated like the letter "c" or "s" with degree 2. Where two bars are required in the top and bottom of the lintel and the bars are not bundled, the bars shall be separated by not less than 1 inch 25 mm. The free end of the stirrups shall be fabricated with or degree 1.

For flat, waffle-grid and screen-grid lintels, stirrups are not required in the center distance, A, portion of spans in accordance with Figure R See Section R It is permitted to bundle two bars in contact with each other in lintels if all of the following are observed:.

Sign Up. Upgrade to premium. Simplify code analysis. Lintels shall be provided over all openings equal to or greater than 2 feet mm in width. Lintels with uniform loading shall conform to Sections R Lintels supporting concentrated loads, such as from roof or floor beams or girders, shall be designed in accordance with ACI It is permitted to bundle two bars in contact with each other in lintels if all of the following are observed: Bars equal to or less than No.

Where the wall thickness is not sufficient to provide not less than 3 inches 76 mm of clear space beside bars total on both sides oriented horizontally in a bundle, the bundled bars shall be oriented in a vertical plane.

steel lintel sizes for openings

Where vertically oriented bundled bars terminate with standard hooks to develop the bars in tension beyond the support see Section R Bundled bars shall not be lap spliced within the lintel span and the length on each end of the lintel that is required to develop the bars in tension. Bundled bars shall be enclosed within stirrups throughout the length of the lintel. Stirrups and the installation thereof shall comply with Section R The maximum clear span of lintels without stirrups designed for nonload-bearing conditions of Table R The maximum clear span of lintels without stirrups in flat walls shall be determined in accordance with Table R Share URL Copy and paste the link below into emails, chats or browsers.

Copy with citation. P Premium Feature This feature is included in premium subscriptions only. Click below to start a free trial.

Start Free Trial. Lintels with uniform loading shall conform to Sections Veneer above openings shall be supported on lintels The minimum required bearing length on each endMy question is what size steel to put in.

This post is not going to help you with the calculations to arrive at what loads you need the lintel to bear — that is for another blog post. The weight of the lintel in kg per metre. The second method involves sitting the lintel back 20mm from the face of the veneer, and have correct seating. The stress in the masonry supporting each end of the lintel should not exceed the allowable unit stress for the type of masonry used. Measure the size of the structural opening i.

How to install a cavity wall lintel — HD. Lintels Sizing — Masonry Lintel Sizing. However, for anyone starting out in the industry, getting to grips with interpreting the load spans for prestressed concrete lintels and steel lintels is not always straight forward.

The first point we need to make is that the load span tables in this post are based on our own products. I need to grout the cells on either side where the lintel bears? Use whatever you want to trim the rest of the opening. I like to debate structural engineering theory — a lot. The steel angles known as shelf anglescan provide all the support, or be attached to the primary structure such as a reinforced concrete frame, to which the load is transferred.

An arch also requires a substantial amount of adjoining wall to stabilise it against the outward thrust of the arch. Steel should be protected against corrosion usually by hot-dip galvanising, the density of which will depend on the corrosive level of the environment, however stainless steel can also be used in highly corrosive environments.

The head of a small opening can be supported by a lintel of galvanised steel, concrete, or reinforced brickwork, as it would be in a loadbearing wall.

When masonry lighter than brick is used over interior angles floor load may be increased by the difference in weight per square metre times the width of the opening.

Ensure lintel is level along its length. Masonry immediately above the lintel should be allowed to cure. Lintels should have a minimum of masonry mm high between the flange and the application level of any form of loading. When the underside of a lintel is exposed, its appearance can be enhanced by the addition of lintel soffit cladding. To avoid lifting strains any lintels other than the shortest lengths should be lifted by at least two people or alternatively by mechanical means.

The reaction at each end of the lintel will be one-half the total uniform load on the lintel, plus a proportion of any concentrated load or partially distributed uniform load. Since in selecting the steel section, the width of the section was determined, that width divided into the required bearing area, [another formula].

I use 5. I am considering a point load near the support. The pitched roof trusses sit on the inner cavity wall in the roof space. If you need any further assistance please let us know or feel free to download our brochure.

I refer you to our latest blog post which states the additional information we need to advise? The inner skin is mm thermal block, outside is mm brick.

How to Make a Lintel Opening in an Existing Concrete Block Wall

I will need mm build in on either side of the 80cm door opening. I know a need 2 concrete lintels mm.

steel lintel sizes for openings

I also know they need to be mm wide so they sit on top of each line of house bricks which are mm. I believe it is a supporting wall; one single brick thickness.

Your email address will not be published. Lintels Sizing — Masonry Lintel Sizing However, for anyone starting out in the industry, getting to grips with interpreting the load spans for prestressed concrete lintels and steel lintels is not always straight forward. The latter allows openings of any length.However, for anyone starting out in the industry, getting to grips with interpreting the load spans for prestressed concrete lintels and steel lintels is not always straight forward.

This post examines the load span tables featured for both concrete and steel lintels and will demonstrate how you should interpret the values within them. This post is not going to help you with the calculations to arrive at what loads you need the lintel to bear — that is for another blog post.

The first point we need to make is that the load span tables in this post are based on our own products. These products are CE marked, and in order to obtain this accreditation, lintels are subject to the most stringent tests under the Construction Products Regulation CPR. This means they are independently tested. The values in our own tables have been independently verified by a third party.

We now have a lintel load span table quick reference guide available, which you can view online, or you can download for free as a PDF. Once you have finished reading this, why not download the guide for future reference. Initially we will make sure we know what values are included in the table. Standard Lengths — This is pretty self-explanatory, and simply means the length of the lintel.

As standard our steel lintels increase in length by mm, the two values represent the length of the lintel that the values in that column relate to. If it is it means the load span details can be applied to any lintel between mm and mm. This value is the load in kiloNewtons kN and simply means the load that this particular lintel can safely bear.

RM — This means Resistance Moment. RM is quite difficult to explain, and quite frankly is best described by a qualified engineer. In very simple layperson terms it is the force as measured by kiloNewtons metre; kNm at which point the lintel breaks. You can find out more about resistance moment here. Understanding the load ratios is vital to gaining an appreciation of lintel selection.

The SWL values in our load span tables are often subject to load ratios. These ratios represent the ratio of load that the lintel can bear as inner leaf to outer leaf. The ratios are different for the different applications. This first load span table is for a standard 50mm cavity lintel. The second table is for a 50mm composite extra heavy duty CXHD lintel.

Looking at SWL figures you can see that if your floor load is a ratio so the same weight is applied on both the inner leaf and outer leaf, then this SL50 at mm can take a load of 8kN on each leaf. If you needed your lintel for an eaves application, then you would use the ratio, which means this lintel would take an inner leaf load of In reality; this is probably not the best lintel for the job.

This level is used for extreme loads. Like I said at the start of the post, the calculations for working out what your load will be is for another post, but once you know this and the other factors affecting lintel selection then you will be able to quickly see which sort of lintel you need to use for the job.

The load span tables for prestressed concrete lintels are very similar to the steel lintel tables with the exception of two values. The principle is the same however; the higher the value, the better the load bearing capabilities on the lintel. Clear span is very simply the length of the opening. If you have a clear span of mm, you will need a mm length lintel to accommodate the required mm span on each side of the opening.

The R15 is a popular concrete product; here you can see the load table values up to a length of mm. Hopefully, this will have provided a simple introduction to lintel load spans and what the values in the load span tables mean.

Do I need a lintel? A guide to lintel installation

However, if you have any questions about lintel selection, load span calculations or lintel specification, our technical team are more than happy to assist. Contact them at technical stressline. It is a block wall. What size angle iron do I need to use to support a single story wood frame home.

Windows will be installed on the bearing block walls.Once an extension has been made weather-proof an opening is normally made through the existing external walls. This can be achieved by removing any existing French doors, patio or window openings and, providing the span of and loading on the existing lintel over the existing doors or windows is not increased, further support is not normally needed.

Any new beam should normally have at least mm bearing overlap onto the existing wall on each side of the opening and the existing wall beneath the bearings are likely to need to be strengthened to prevent crushing of them. This may require the installation of an area of dense concrete cast in-situ or pre-castknown as a padstones to spread the load. The size of padstones will vary depending on the circumstances of the case in hand.

If the beam is steel then it should normally be protected against fire so that it will have 30 minutes resistance to fire if measured in a standard test. There are different ways that this may be achieved, but the most common is the use of two or more layers of properly fixed plasterboard - the thickness of which will depend on the manufacturer's specification. If an exposed timber beam is preferred then a calculation is generally required to demonstrate how much inherent fire resistance it has - dependent on its size and species of timber.

A concrete beam, which would normally have steel reinforcement inside it, generally has adequate fire resistance properties, providing the steel inside is adequately covered by the concrete. You are here: Home Do you need permission? Common projects Extensions.

Pages in Extensions Planning Permission Prior approval Is building regulations approval needed for an extension?Brickwork needs to be supported over openings. There are five methods of doing this: brick arches, steel bars or angles, prefabricated reinforced concrete, prefabricated brickwork and directly from the reinforced concrete structure.

The steel angles known as shelf anglescan provide all the support, or be attached to the primary structure such as a reinforced concrete frame, to which the load is transferred. Brick arches of various curvatures are a traditional method of carrying brickwork over an opening. Constructing an arch requires a timber formwork "centering" to be constructed first, and removed after the arch is completed and the mortar sufficiently set.

If the radius of curvature is large enough, it can be achieved by using ordinary rectangular bricks with slightly tapered joints; but in a tight arch, the bricks have to be tapered, which is much more time-consuming. An arch also requires a substantial amount of adjoining wall to stabilise it against the outward thrust of the arch. See Brickwork Design - Arches.

Short spans, for example up to mm, can be spanned by a flat bar, but longer spans need angles or stronger sections. As the lintel will extend not less than mm beyond the opening AS4. Steel should be protected against corrosion usually by hot-dip galvanising, the density of which will depend on the corrosive level of the environment, however stainless steel can also be used in highly corrosive environments.

See Metal ties and Inclusions under Weather Resistance. The bottom of the steel angle will, in most cases, be exposed to view at bed joint level. This can be left in its galvanised state or painted for aesthetic reasons.

If a brick only soffit is desired then the bed joints of a number of courses above the opening can be reinforced with galvanised steel rods or proprietary stainless steel helical strips such as "Helifix". The installation will need to be designed by an engineer and AS 5.

Alternatively, a proprietary galvanised steel bar lintel system such as "Hesbia" embedded in the bed joint above the opening can be used. One lintel per leaf will be needed. In these installations, it is important that the engineer's or manufacturers' instructions are properly followed.

Shelf angles are typically bolted to the supporting frame and the brickwork built from it. Proprietary systems of inserts in the reinforced concrete with slotted angles allow for adjustment to ensure that the angle is where it should be.

Flashing and weep holes will need to be provided as with lintels supported on brickwork. Toga building, York St. The heights of these lintels are in multiples of brick courses and they are the full width of a leaf. They are not designed for use with face brickwork and need to be rendered to be visually acceptable. The load carrying capacity of the precast concrete lintels increases significantly when they act compositely with the brickwork above and spans of mm can be readily achieved.

Fire ratings range from 60 to minutes. Brickwork readily meets most fire rating requirements. However, in some situations an exposed steel lintel may need the same fire rating as the brickwork, but it usually easier to support the brickwork in other ways than try to fire rate the steel. The limitations imposed on openings in a loadbearing wall are removed when there is a loadbearing frame and the wall is simply an infill.

The heads over openings can be supported in one of two main ways. The latter allows openings of any length.

It requires the head to be aligned with the underside of the floor slab or beam above. The illustration of Hilversum Town Hall Willem Dudok, architect, is typical of a style that uses large expanses of brickwork supported above very wide openings. It is obvious that the brickwork above the openings is supported by the structural frame of the building, rather than by a lintel.

The head of an opening can be aligned with the bottom of a floor beam by locating a supporting nib or shelf angle at the bottom edge of the beam. It may be difficult to detail the shelf angle if it is exposed at the head, and it would not be feasible to fire-protect it in this position.


thoughts on “Steel lintel sizes for openings